MVW2-8A –AC***
MVD812K-02-8A-NO.11-DC110
MVD812K-02-10A-NO.11-DC110
YS336TF04L8BC9
S-MVS2-CD
S-MVS2-EF
MVD813K-02-10A–DC24
MVS2-20A-AC110
4N3S102K-W6
453S202C-E2K -NO.12-DC24
MVS2N-08-E3K-20A-NO.**-DC48
MVS813K-02-10A-NO.**- DC48
MVS812K-02-10A-NO.8 - DC125
S202JF02L7DG4
MVW 7NR 08D-25A-DT-DC24V
MVW 344N 08D-25A-DT-B-DC24V
P/N#453S102N-D6-G30555
Heavy duty type solenoid valve with reliable functions suitable for severe operating conditions.Solenoid with strong suction power
Pilot valve resistant to contaminated air
Highly reliable control mechanism
Model code
Closed center MVPC1 MVPC2
Center open to exhaust MVPO1 MVPO2
Center open to pressure MVPE1 MVPE2
Port size Rc3/8 Rc1/2 Rc3/4 Rc1 Rc1 1/4 Rc1 1/2
10A 15A 20A 25A 32A 40A
Working pressure 0.12~0.7MPa
Ambient temp. -20~50℃
Effective area of valve 35mm 2 60mm 2 140mm 2 180mm 2 250mm 2 350mm 2
Rated voltage AC100,110,200,220V(50/60Hz) DC24,48,100,110,200,220V
MVW2-8A –AC***
MVD812K-02-8A-NO.11-DC110
MVD812K-02-10A-NO.11-DC110
YS336TF04L8BC9
ngti="">S-MVS2-CD
ngti="">S-MVS2-EF
MVD813K-02-10A–DC24
MVS2-20A-AC110
4N3S102K-W6
453S202C-E2K -NO.12-DC24
MVS2N-08-E3K-20A-NO.**-DC48
MVS813K-02-10A-NO.**- DC48
MVS812K-02-10A-NO.8 - DC125
S202JF02L7DG4
MVW 7NR 08D-25A-DT-DC24V
MVW 344N 08D-25A-DT-B-DC24V
2. Konan 454 series direct piping type compact explosion-proof 5-port solenoid valve spool valve
Compact type explosion-proof solenoid valve effectively layouting a terminal box to ensure easy wiring. Connection interface can be 0ed direct piping type or NAMUR standard model.
Model code
Return 454S101C 454S102C 454S202C 454S203C
Hold 454D101C 454D102C 454D202C 454D203C
Port size Rc1/8 Rc1/4 Rc3/8
Effective area of valve 10mm2 22mm2
Working pressure 0.15~0.7MPa
Ambient temp. d2G4 : -5~60℃ Exd II BT4 : -5~40℃
Solenoidf
Rated voltage AC100V,110V,200V,220V(50/60Hz) DC24V
Temperature rise ≦60℃
Insulation class JIS C4003 Class H
Power consumption AC: 5.5 VA (60 Hz) / 7.5 VA (50 Hz), DC: 4 W
Response time ≦0.05 sec
Explosion-proof standard Explosion-proof enclosure construction d2G4 and Exd II BT4
3. Konan 4N4 series NAMUR standard model compact explosion-proof 5-port solenoid valve spool valve
5-port solenoid valve for operation change of a pneumatic actuator.
This product incorporates a bypass valve in the body and has a speed controller to adjust exhaust pressure as a standard. Valve size is designed based on the NAMUR standard.
Model code
Return 4N4S102K
Hold 4N4D102K
Port size Rc1/4
Effective area of valve 10mm2
Working pressure 0.15~0.7MPa
Ambient temp. d2G4 : -5~60℃ Exd II BT4 : -5~40℃
Solenoid
Rated voltage AC100V,110V,200V,220V(50/60Hz) DC24V
Temperature rise ≦60℃
Insulation class JIS C4003 Class H
Power consumption AC: 5.5 VA (60 Hz) / 7.5 VA (50 Hz), DC: 4 W
Response time ≦0.05 sec
Explosion-proof standard Explosion-proof enclosure construction d2G4 and Exd II BT4
Accessories
Bolt for mounting of TA2 rotary actuator, packings, silencer with throttle valve
4. Konan 5-port Solenoid Valves for Heavy-Duty Spool valve
Heavy duty type solenoid valve with reliable functions suitable for severe operating conditions.
Solenoid with strong suction power
Pilot valve resistant to contaminated air
Highly reliable control mechanism
Model code
Single type MVW2 MVS2
Double type MVD2
Port size Rc1/4 , Rc3/8 Rc3/8 Rc1/2 Rc3/4 Rc1
8A , 10A 10A 15A 20A 25A
Working pressure
0.12~0.7MPa
Ambient temp.
-20~50℃
Effective area of valve 15mm 2 60mm 2 70mm 2 150mm 2 165mm 2
Rated voltage AC100,110,200,220V(50/60Hz) DC24,48,100,110,200,220V
5. Konan Explosion-Proof Drip-Proof 3-port Solenoid Valves MVS300K/MVD300K series
Compact type solenoid valve series with accumulated "proof" technologies.
Double-acting (hold type) explosion-proof solenoid valve incorporates a magnet-latched solenoid. Its compact design has been achieved by employing single conduit outlet.
Return Hold Return Hold
Model code Drip-Proof type
MVS301K-02 MVD301K-02 MVS311K-02 MVD311K-02
Explosion-Proof type Pressure-resistant packing system
MVS302K-02 MVD302K-02 MVS312K-02 MVD312K-02
metal conduit system
MVS303K-02 MVD303K-02 MVS313K-02 MVD313K-02
Structure of the main valve Direct-acting poppet valve
Port size Rc1/4
Effective area of valve 1mm2(0.05) 4mm2(0.2)
Working pressure 0~0.7MPa 0~0.1MPa
Ambient temp. -20~60℃
Explosion-proof standard d2G4
6. Konan Explosion-Proof Drip-Proof 4-port Solenoid Valves MVS800K/MVD800K series Ceramic slide valve
Return Hold Model code Drip-Proof type
MVS811K-02 MVS801K-03 MVD811K-02 MVD801K-03
Explosion-Proof type Pressure-resistant packing system
MVS812K-02 MVS802K-03 MVD812K-02 MVD802K-03
metal conduit system
MVS813K-02 MVS803K-03 MVD813K-02 MVD803K-03
Structure of the main valve Ceramic slide valve Pilot-acting
Port size Rc1/4 Rc3/8 Rc3/8 Rc1/2 Rc1/4 Rc3/8 Rc3/8 Rc1/2
Effective area of valve
16mm2 (0.9) 18mm2 (1.0) 55mm2 (3.0) 60mm2 (3.3)
Working pressure 0.12~0.7MPa
Ambient temp. -20~60℃
Explosion-proof standard d2G4
7. Konan Explosion-Proof Drip-Proof 5-port Solenoid Valves 453S/453D series Spool valve
Return Hold Return Hold
Model code Pressure-resistant packing system
453S202C-E2K 453S203C-E2K 453D202C-E2K 453D203C-E2K 453S403C-E2K 453S404C-E2K 453D403C-E2K 453D404C-E2K
metal conduit system
453S202C-E1K 453S203C-E1K 453D202C-E1K 453D203C-E1K 453S403C-E1K
453S404C-E1K 453D403C-E1K 453D404C-E1K
Structure of the main valve Pilot-acting spool valve
Port size Rc1/4 Rc3/8 Rc1/4 Rc3/8 Rc3/8 Rc1/2 Rc3/8 Rc1/2
Effective area of valve 22mm2(1.2) 40mm2(2.2)
Working pressure 0.2~0.7MPa
Ambient temp. -5~50℃
Explosion-proof standard d2G4
MVS302K-02 MVS312K-02 MVS303K-02 MVS313K-02 MVD313K-02 MVW71-15A-WY-AC110-TB1-15A MVS803K-02-8A-DC24 MVW7R-20A AC240V C-M01A-24 MVS812K-02-10A-NO.12-AC100V 453S102C- L2-C00 453S102C-L2-C00 MVW1-8A-W*-AC***-TB1-*** RV2-14-40A MVP01-20A, TYPE:CP51-N-B-TF-140X190-I
8. Konan Explosion-Proof Drip-Proof 5-port Solenoid Valves MVPCF(N)/MVPEF(N)/MVPOF(N) series Spool valve
Closed center Center open to pressure Center open to exhaust Closed center
Center open to pressure
Center open to exhaust
Model code Drip-Proof type
MVPCF-03-E3K MVPEF-03-E3K MVPOF-03-E3K MVPCN-08-E3K
MVPEN-08-E3K MVPON-08-E3K
Explosion-Proof type Pressure-resistant packing system
MVPCF-03-E2K MVPEF-03-E2K MVPOF-03-E2K MVPCN-08-E2K
MVPEN-08-E2K MVPON-08-E2K
metal conduit system
MVPCF-03-E1K MVPEF-03-E1K MVPOF-03-E1K MVPCN-08-E1K
MVPEN-08-E1K MVPON-08-E1K
Structure of the main valve Pilot-acting spool valve Port size
Rc1/4·Rc3/8·Rc1/2 Rc3/4·Rc 1
Effective area of valve
40mm2(2.2)·55mm2(3.0)·70mm2(3.8) 175mm2(9.5)·185mm2(10.0)
Working pressure 0.2~0.7MPa 0.12~0.7MPa
Ambient temp. -5~60℃ -20~50℃
Explosion-proof standard d2G4
9. Konan Explosion-Proof Drip-Proof 5-port Solenoid Valves MVS2F(N)/MVD2F(N) series Spool valve
Port size Rc1/4·Rc3/8·Rc1/2 Rc3/4·Rc 1
Effective area of valve 40mm2(2.2)·55mm2(3.0)·70mm2(3.8) 175mm2(9.5)·185mm2(10.0)
Working pressure 0.2~0.7MPa 0.12~0.7MPa
Ambient temp. -5~60℃ -20~50℃
Explosion-proof standard d2G4
10. Konan Intrinsic Safety 414/416 series 5-port solenoid valves Spool valve / Ceramic slide valve
Return Kind of barrier to combine i2G4 MTL728+
414S302C-Yi 414S303C-Yi 414S603C-Yi 414S604C-Yi 416S302C-Yi
416S303C-Yi 416S603C-Yi 416S604C-Yi
ExiaⅡBT5 SAF3-5
414S302M-Yi 414S303M-Yi 414S603M-Yi 414S604M-Yi 416S302M-Yi
416S303M-Yi 416S603M-Yi 416S604M-Yi
In the case of other explosion-proof barriers and combination *1
Structure of the main valve Pilot spool type Pilot ceramic slide type
Port size Rc1/4 Rc3/8 Rc1/2 Rc1/4 Rc3/8 Rc1/2
Effective area of valve 25mm2 30mm2 51mm2 60mm2 24mm2 28mm2 51mm2 60mm2
Working pressure 0.2~0.7MPa 0.12~0.7MPa
Ambient temp. -5~50℃ -10~60℃
Explosion-proof standard Intrinsic safety construction
Operating condition
1. Use with specified safety barrier.
For i2G4 explosion-proof valves, use them with MTL728+ safety barrier.
For Exia II BT5 explosion-proof valves, use them with the safety barrier SAF3-5 or that meets the
conditions described below (note *1).
2. Parts and connections cannot be changed.
3. Use 1 explosion-proof barrier for each solenoid valve.
11.Konan Intrinsic Safety 454 series 5-port solenoid valves spool valve
Intrinsic safety valves can be used for applications that require similar explosion class/ignition degree to d2G4 or Exd II BT5 type (explosion-proof enclosure construction). Without need for expensive connection tools and complex installation work that are inevitable for explosion-proof enclosure types, the intrinsic safety valves achieve highly reliable explosion-proof performance.
Return Hold Kind of barrier to combine
454S202C 454S203C 454S403C 454S404C 454D202C 454D203C 454D403C 454D404C
SAF3-5
454S202M 454S203M 454S403M 454S404M 454D202M 454D203M 454D403M 454D404M
In the case of other explosion-proof barriers and combination *1
Structure of the main valve Pilot spool type
Port size
Rc1/4 Rc3/8 Rc1/2 Rc1/4 Rc3/8 Rc1/2
Effective area of valve 22mm2 40mm 22mm 40mm2
Working pressure 0.2~0.7MPa
Ambient temp. -5~50℃
Explosion-proof standard Intrinsic safety construction
Operating condition
- Use with specified safety barrier
- For i2G4 explosion-proof valves, use them with MTL728+ safety barrier.
- For Exia II BT5 explosion-proof valves, use them with the safety barrier SAF3-5 or that meets the
- conditions described below (note *1).
- 2. Parts and connections cannot be changed.
- 3. Use 1 explosion-proof barrier for each solenoid valve.
12. Konan Intrinsic Safety Solenoid Valves 414/416 series 5-port solenoid valves Terminal block ZA Spool valve/Ceramic slide valve
Return
Kind of barrier to combine
ExiaⅡBT5
SAF3-5
414S302M-YAi 414S303M-YAi 414S603M-YAi 414S604M-YAi416S302M-YAi
416S303M-YAi 416S603M-YAi 416S604M-YAi
In the case of other explosion-proof barriers and combination *1
Structure of the main valve Pilot spool type
Pilot ceramic slide type Port size
Rc1/4 Rc3/8 Rc1/2 Rc1/4 Rc3/8 Rc1/2
Effective area of valve
25mm2 30mm2 51mm2 60mm2 24mm2 28mm2 51mm2 60mm2
Working pressure 0.2~0.7MPa 0.12~0.7MPa
Ambient temp. -5~50℃ -10~60℃
Explosion-proof standard Intrinsic safety construction
Operating condition
1. Use with specified safety barrier.
For Exia II BT5 explosion-proof valves, use them with the safety barrier SAF3-5 or that meets the
conditions described below (note *1).
2. Parts and connections cannot be changed.
3. Use 1 explosion-proof barrier for each solenoid valve.
note *1
In the case of other barriers and combination
Konan 454, 414, 416 series intrinsic safety solenoid valves have passed equipment qualification tests for intrinsic safety solenoid valve.
The valves can be used in combination with the safety barrier that meets the following conditions. (The valves can be used with insulation barrier that does not need type A ground.)
The barrier used in combination with the valves should be the one that has passed equipment qualification tests for a barrier and that meets the following conditions.
Safety retention voltage
Maximum voltage of a intrinsic safety circuit
Less than 29.4V
Maximum current of a intrinsic safety circuit
Less than 93.8mA
Electric power of a intrinsic safety circuit
Less than 0.689W
Performance classification / Group
Performance classification
ia
Group
ⅡB or ⅡC
Allowable inductance (Lo) and capacitance (Co) for an intrinsic safety circuit and relationship between inductance (Lo) and capacitance (Cw) for external connections to the intrinsic safety circuit
Allowable inductance of a intrinsic safety circuit:Lo≧Li+Lw(mH)
Allowable capacitance of a intrinsic safety circuit:Co≧Ci+Cw(μF)
13. Konan Intrinsic Safety Solenoid Valves Explosion barrier SAF100-5
Intrinsic safety explosion barrier is an explosion-proof device with single channel, Zener-diode DC circuit that enables interactive electric signaling without short circuit while controlling energy transmission in order to prevent ignition in explosive atmosphere.
1.Applicable to Zone 0.
2.A-class ground is not necessary since the input and output are insulated
each other.
3.When serially connected to a transmission circuit, the barrier protects
the circuit and components in hazardous area from being affected by
a serious accident in the non-hazardous area.
4.Despite in the hazardous location, conventional wiring is available.
5.Intrinsical proof of operational signal is figured out easily and at lower
cost.
6.SAF100-5 safety barrier employ crimping terminal wiring method.
7.As SAF100-5 safety barrier has protection circuit, it will be not broken
if you wired in the wrong polarity.
8.LED indicates the condition of the input and output
Model code SAF100-5
Explosion-proof construction Intrinsic safety construction(ExiaⅡC)
Rated voltage DC24V±10%
Maximum voltage of a intrinsic safety circuit DC29.4V
Max. allowable voltage DC25.95V
Maximum current of a intrinsic safety circuit 93.8mA
Electric power of a intrinsic safety circuit 0.689W
Ambient temp. -20~50℃
Basic circuit figure
Does not need A-class ground.
Operating condition
1.Place the valve in non-hazardous area.
2.Perform single grounding using type A ground.
3. Parts and connections cannot be changed.
4. Use with specified solenoid valves.
5. Allowable inductance for external
connection: 2mH / Capacitance: 0.05 μF
14. Konan Intrinsic Safety Solenoid Valves Explosion barrier SAF3-5 , MTL728+
Intrinsic safety explosion barrier is an explosion-proof device with single channel, shunt-diode DC circuit that enables interactive electric signaling without short circuit while controlling energy transmission in order to prevent ignition in explosive atmosphere.
1.Applicable to Zone 0.
2.When serially connected to a transmission circuit, the barrier protects
the circuit and components in hazardous area from being affected by
a serious accident in the non-hazardous area.
3.Despite in the hazardous location, conventional wiring is available.
4.Intrinsical proof of operational signal is figured out easily and at lower
cost.
5.As SAF3-5 safety barrier has protection circuit, it will be not broken
if you wired in the wrong polarity.
6.SAF3-5 safety barrier employ crimping terminal wiring method.
Model code SAF3-5 MTL728+
Explosion-proof construction
Intrinsic safety construction(ExiaⅡB) Intrinsic safety construction(i2G4)
Rated voltage DC24V±5%-
Max. working voltage - DC25.5V
Max. allowable voltage - DC26.6V
Safety retention voltage AC/DC 250V
Rating of a fuse 50mA
Ambient temp. -20~60℃ -10~60℃
Basic circuit figure
Operating condition
1.Place the valve in non-hazardous area.
2. Parts and connections cannot be changed.
3. Use with specified solenoid valves.
4. Allowable inductance for external connection: 10mH / Capacitance: 0.5 μF
4. Allowable inductance for external connection: 1mH / Capacitance: 0.05 μF