BHC-301A

 
Price: N/A
Delivery: In 30 days
Expiry: Long-term
Edit time: 2024-04-10 16:00
Hits: 899
 
Supplier Information
Product Description
 BHC-301A Model No.: BHC-301A 

Specifications 
Model No.: BHC-301A (Hot and cold type)
Special use for operating rooms and burn and scald patients
[4℃~42℃]

Suitable for: Operating rooms, anesthesia, ICUs (intensive care units), burn and scald centers, observation rooms



Instruction manual of operating the host (main engine)

      

Water shortage displaying lamp: Indicating that the water level is too low.

 

2.Flow-abnormal lamp: Indicating that the system flow is abnormal.

 

3.High water temperature protection lamp: Showing that the water temperature is too high and that it is in a protection status.

 

4.Low water temperature protection lamp: Showing that the water temperature is too low and that it is in a protection status.

5.Abnormal body temperature sensing lamp: Displaying that the function of body temperature detection is abnormal.

6.Abnormal water temperature sensing lamp: Displaying that the function of water temperature detection is abnormal.

7.Body temperature lamp: Displaying that the temperature monitoring function is being executed.

8. Auto lamp: Displaying that the automatic body temperature control function is being executed.

9. Manual lamp: Displaying that the manual temperature control function is being executed.

10. Centigrade lamp: Displaying the selecion of Centigrade temperature.

11.Fahrenheit lamp : Displaying the selecion of Fahrenheit temperature.

12.Water temperature setting indicator lamp: Displaying that the current water temperature has been set.

13.Body temperature setting indicator lamp: Displaying that the current body temperature has been set.

14.Temperature cooling-down lamp: Indicating that the current cooling operation has been set.

15.Warm setting lamp: Indicating that the current temperature or the temperature has reached to the setting value

16.Temperature warming-up lamp: Indicating that the current warning-up operation is being executed.

17.Water temperature Display screen

18.Temperature-setting display screen

19.Body temperature display screen

20.Centigrade/Fahrenheit selection key: Selecting Centigrade or Fahrenheit temperature

21. Test button: Testing panel displays and LED lamps whether they are normal or not.

22.Alarm cancel button: When an alarm occurs, use it to stop the buzzer. 

23.ON / OFF button: Switch button

24.Temperature accumulation setting button: Adjusting the temperature to rise up.

25.Temperature decreasing setting button: Adjusting the temperature to dro down.

26.Setting button: Press this button to enter the temperature adjustment status. Before executing the change of various functions it is necessary to press it to reset the temperature.

27.Manual button: After adjusting the setting of temperature, press it to enter the manual water temperature controlling function.

28.Auto button: After adjusting the setting of temperature, press it to enter the automatic body temperature controlling function.

29. Body temperature button: After adjusting the setting of temperature, press to enter the body temperature monitoring function.

 

Automatic operation for body temperature


BHC-301A can be set for the actual needs of the human body temperature as a controlling basis to control the heating or cooling of the water mattress and to achieve the purpose of controlling the body temperature. We call it [automatic body temperature controlling]. The method is to connect the sensor between BHC - 301A and the patients at both ends to set the desired value of the patient body temperature by pressing "automatic body temperature" button, and then BHC - 301A will automatically determine the required warming-up or cooling-down water temperature to achieve the purpose of controlling patient temperature.


Operation processes are as follows:

The main power switch indicator lights up.

HC-301A’s microcomputer self-detecting body and water temperature indicators show "As the normal system," and five seconds later the display is off. Afterwards, the monitors on the right and left sides show the body temperature and water temperature respectively.


Press the body temperature detection system (the temperature set by the body temperature) to operate the warming-up procedure. When the warming-up LED is lit, it indicates that the warming-up system is being operated. When the body temperature detection system (the temperature set by the body temperature) has been set, the temperature setting LED will be always lit indicating that the body temperature of the patient has reached to the required value.

When the desired body temperature value set by the user is not in the correct range (10 ℃ ---> 42 ℃), press "Auto button", and then the temperature desired value will flash to alert the user to re-key in the correct value; at this time, the user has to re-press "the setting button " to key in the correct value, and then press " the Auto button” by which the system can correctly be operated.

If the above processes occur an alert status, the warning lamp on the left side corresponding to the operation panel will light up; and the buzzer will continuously beep to warn the system to suspend the operation. At this time, the user should exclude this abnormal condition to resume the normal operation system.

 The sound of buzzer alarm can be cancelled by pressing "alert cancel button". At this time, the warning lamp is indicated by flashing.


After the above operation has been completed, BHC-301A’s operation at this moment is under “automatic controlling mode of the body temperature”; and the user should continue to monitor the operation status of the patient and the machine body. If necessary, make an appropriate disposition.

Manual operation for water temperature


BHC-301A can be set for the actual needs of the water temperature as a controlling basis to control the heating or cooling the water mattress and to achieve the purpose of controlling the water temperature. We call it [manual water temperature controlling]. The method is to open the main engine by pressing the "Power ON / OFF button" for setting the desired value of the water temperature. Further press "Water temperature manual button”, then BHC - 301A will automatically determine, according to the water temperature and the set temperature, the required warming-up or cooling-down water temperature to achieve the purpose of controlling water  temperature.



Operation processes are as follows:

 

The main power switch indicator lights up.

HC-301A microcomputer self-detecting body and water temperature indicators show "As the normal system," and then five seconds later the display is off. Afterwards, the monitors on the right and left sides show the body temperature and water temperature respectively.


After the above operation has been completed, BHC-301A’s operation at this moment is under “water temperature controlling mode set by manual”; and the user should continue to monitor the operation status of the patient’s and the machine’s body. If necessary, make an appropriate disposition. 

 


After the above operation has been completed, BHC-301A’s operation at this moment is under “water temperature controlling mode set by manual”; and the user should continue to monitor the operation status of the patient’s and the machine’s body. If necessary, make an appropriate disposition. 

 
The method of operating body temperature monitoring 

The main purpose of body temperature monitoring function of BHC-301 A is to use the body temperature monitoring function in BHC-301A to monitor the changes of the patient’s body temperature with a temperature sensor; however, it is only a monitoring function; and it does not perform the warming-up or cooling-down process.



Operation processes are as follows:

 

 

If the above processes occur an alert status, the warning lamp on the left side corresponding to the operation panel will light up; and the buzzer will continuously beep to warn the system to suspend the operation. At this time, the user should exclude this abnormal state to resume the normal operation system.

 

 


Function of selecting the displays of Centigrade and Fahrenheit 
Press the "Centigrade/Fahrenheit selection button" each time to change the temperature display for Centigrade or Fahrenheit.

The method of discharging the circulating water
       The use of the circulating water in this system should be regularly replaced. The method is as follows:


Description of the fuse replacement 
Process of fuse replacement for BHC-301A:

o  Loosen five screws in the glove box on the back of BHC-301A.
o  Open the glove box in which the fuse at the top of the inner switchboard can be found.  
o replac the fuse with a new one ( 15A/250VAC)
o Close the glove and lock the screws accordingly.

 


 Cautions of other matters::
1. Please read the operation manual before using this equipment carefully. 
2. Please use a separate power socket and 15A fuse. 
3. Make sure that the model of the power supply voltage and frequency used in this machine before plugging in the power cord.
4. This device must be vertical to the horizontal floor; and do not place it lying flat. 
5. based on patient’s safety considerations, this machine is required a continuous monitoring in the course of use and the qualified medical physicians responsible for clinical applications and professional judgment. 
6. When the alarm sounds, the operator should immediately deal with the alarm occurring, troubleshooting, and re-operate thereof.
7. This device should be far from explosive materials and flammable gas.

 Accessories 
Host (main engine) Model No.: BHC-301A
Mattress Model No.: LVC-203
Silicone tube  2 pieces
Temperature sensor (Body temperature detector)
The host (main engine) can be used with small mattresses (LVC-201)

 

Item

Specifications

Model No.

BHC-310A (Hot and cold type)

Power

110V/220V  50Hz/60Hz

P consumption

600 W

Host (main engine) weight

43kg

Host (main engine) dimensions

38cm (L) X 55cm (W) X 87cm (H)

Temperature setting range

4℃~42℃

Mattress dimensions

LVC-203 :165cm (L) X 65cm (W) X 1cm (H)
LVC-201: 50cm (L) X70cm (W) X 1cm (H)

 


TPU material: Anti-mite and anti-bacterial mattress 
Use at ease without any electromagnetic waves and electric leakages.
Device for safety: When the host (main engine) dumps or has water shortage therein, it will automatically shut down. 
Prevention from burn and scald: When the temperature reaches to 45℃ (113℉), the heating function will automatically stop. 
Functions: Getting warm in the winter, home health care, promoting blood circulation, improving metabolism, and relieving muscle soreness.

  Cautions:

  1. When it is used for the disabled and the temperature setting range is 35℃~ 45℃; and there should have caregivers by the side of the sick to take care of them.
  2. A power-off device built-in. When water shortage and the dumping of the host (main machine) occur, it will automatically cut off the power supply. After that, reboot it accordingly.
  3. LVC-202 bed is resistant to high and low temperature and has anti-mite anti-bacterial functions; and the eco-friendly TPU mattress is also a heat sink. It will have a better effect if bed cover or sheath is used.
more>Related Products of this Supplier
BHC-101 BH-102 BH-101 BHC-301A LW-080D LW-120D LW-130D LW-240D